16 × 12 with 16 in joists
- Decking
- 29 boards of 16' 0"
- Joists
- 13 × 2x10
- Beam
- Triple 2x10
- Posts
- 3 at 8' 0"
- Footing
- 21 in · 23 bags each
JoyOne factory · deck takeoff
Two dimensions, one species, one spacing. The frame redraws as you type and the whole takeoff follows: decking rows, joists, the beam that spans between posts, the footing under each post, the bags of concrete and a printable purchase list.
29 boards · 13 joists · Triple 2x10 · 3 posts
21 in footings 3' 6" deep · 69 bags of concrete · 2x10 at 16 in o.c.
16' 0" × 12' 0" · 4.88 m × 3.66 m · Southern pine
Example prices — edit any line to match your store. Nothing here is a national average.
| Item | Quantity | Your unit price | Line |
|---|---|---|---|
| Decking29 boards with 10% waste | 464 linear ft | $ | $974.40 |
| Joists12 ft stock | 13 pieces | $ | $182.00 |
| BeamTriple 2x10 | 48 linear ft | $ | $163.20 |
| Postsat 8' 0" | 3 pieces | $ | $54.00 |
| Concrete23 per footing | 69 bags | $ | $517.50 |
| Joist hangers13 hangers, one per joist at the ledger | 13 pieces | $ | $20.80 |
| Ledger boardbolted to the band joist, not to the siding | 1 pieces | $ | $22.00 |
| Total | $1,933.90 |
Every number below comes from the same engine that runs in the browser, at build time, so the examples cannot drift from the calculator above.
A deck has two dimensions and they are not interchangeable. The one measured along the house is the length: it is the direction the decking boards run, the direction the beam runs, and the number the joists are spaced along. The one measured out from the wall is the depth: it is how far every joist has to reach, and it is the number that decides the joist size. Type them the wrong way round and the calculator will happily size a 16 ft joist that does not exist in a table that stops at 18 ft.
Measure the length at the wall, not at the outer edge, because the house is usually straight and the outer edge is whatever the builder made it. Measure the depth from the siding to where you want the rim, and write down both numbers to the nearest inch rather than the nearest foot: an extra 3 in of depth can be the difference between a 2x8 and a 2x10, which is the difference between a 12 in and a 14 ft span at 16 in on centre.
Then decide what the deck attaches to. A ledger bolted through the siding into the band joist is the usual case and it is what the prescriptive tables assume; a free-standing deck with a rim joist at each end and a beam under both does not depend on the house at all, which is the right answer when the siding is stucco, when the band is not accessible, or when the deck sits away from the wall. The two cases change the joist count by one and the hanger count by all of them.
Before you type a number
The order is fixed and it is why this page is one calculator rather than five. The depth picks the joist size out of Table R507.6 at your spacing. The joist span picks the column of the beam table, because a beam carries joists and a longer joist loads it more. The beam span becomes the maximum post spacing. The post spacing times the joist span is the tributary area that sizes the footing in Table R507.3.1. Change the depth by a foot and all four numbers can move.
The default here is 16 ft along the house by 12 ft out, Southern pine, 16 in on centre. A 2x8 at 16 in reaches 11 ft 10 in, which is 2 in short of 12 ft, so the calculator picks the next size up and says so: a 2x10 spans 14 ft 0 in at the same spacing. That is not a rounding quirk, it is the table doing its job, and it is the single most common place a DIY takeoff goes wrong — buying the 2x8 because the area maths worked.
The beam then has to carry those 12 ft joists across 8 ft post spacing. In Southern pine a double 2x10 spans 7 ft 4 in under 12 ft joists, which is short; a triple 2x10 spans 9 ft 2 in, which is not. So the default deck gets a triple 2x10 and three posts at 8 ft. Two posts would need 16 ft of beam span, which no built-up 2x lumber in the table reaches at that joist span, and that is a real answer rather than a failure.
The board count is a division on a pitch, and the pitch is the dressed width plus the gap. A 5/4x6 is 5 1/2 in wide once it is planed, not 6 in, and a 3/16 in gap makes a 5 11/16 in pitch. Across 12 ft of depth that is 144 ÷ 5.6875 = 25.3, so 26 rows — and 26 boards of 16 ft, because each row is one board long when the deck is 16 ft and the stock is 16 ft. Add the 10% allowance and the order is 29 boards, or 464 linear feet.
The gap is not cosmetic. It drains, it lets the board dry on both faces, and it gives the board somewhere to go when it swells. A quarter inch reads as a tight deck and is what most composite boards specify; three sixteenths is the common wood figure and the one the table’s "approximately 1/8 in" note is near. Anything wider than a quarter inch on a wood deck is a design decision, not a default.
Run the boards diagonally and both numbers change. A board laid at 45° covers pitch ÷ √2 across the depth, so it takes more rows to cross the same deck, and each board has to be long enough to reach across the depth diagonally — 12 ft × √2 = 17 ft, which means two pieces per row out of 12 or 16 ft stock and a joint that must land on a joist. That is why the diagonal allowance here is 15% rather than 10%: the cut ends are large and they are at both ends of every board.
Each post carries the deck surface between it and its neighbours, so the tributary area is the post spacing times the joist span. For the default deck that is 8 ft × 12 ft = 96 sq ft, which is 4,800 lb of design load at 50 psf. On 2,000 psf soil that needs 2.4 sq ft of bearing, and Table R507.3.1 reads the 100 sq ft row for it: a 21 in round footing. On 1,500 psf soil the same post needs 25 in. Those are big numbers, and they are the reason deck footings are usually tubes rather than the 12 in bag-mix holes people dig.
The footing volume follows from that diameter and the depth you set. A 21 in round footing 42 in deep is 8.42 cu ft of concrete, which is 23 bags of 50 lb fast-setting mix, or 15 bags of 80 lb mix. Multiply by three posts and the deck needs 69 bags — over 3,400 lb of concrete, which is a pallet and a half-ton of material handling. Cut the depth to the 36 in frost line and it is 20 bags a footing instead of 23; that is the arithmetic that makes people reconsider a deeper hole.
Two things the table does not do: it does not check the post itself, and it does not check the connection. Table R507.4 limits post height by tributary area, and R507.3.1’s footnote requires the footing to give the post complete bearing and a connector or 12 in of embedment for lateral restraint. A 6x6 post that is 14 ft tall on a 96 sq ft tributary is at the edge of its table row; a 4x4 is not in the table at all at that area.
It will not design your ledger connection, your guard, your stairs or your lateral bracing. Those are the parts that fail, and they fail for reasons a span table cannot see: a ledger bolted into siding instead of the band, a guard post lagged into a rim joist that is only nailed, a stair stringer that lands on a footing that heaved. IRC R507.9 through R507.11 cover them in more detail than a calculator can, and an inspector will check them before the decking goes on.
It will not tell you that a hot tub is fine. Forty psf is a crowd of people, not a tonne of water in one corner. The load page shows what a tub does to the numbers and stops there, because the prescriptive tables are not written for a 500 psf point load and no amount of arithmetic on this page makes them apply.
What it does do is show its working. Every span on the page is a cell from a numbered table, every table is linked at the bottom with the date it was read, and every arithmetic step is a pure function with a test — including the ones that would be easy to fudge, like the pitch division and the bag rounding. If a number here disagrees with your lumber yard’s chart, the source is one click away and the cell is quoted verbatim.
About 26 rows of 5/4x6 decking at a 3/16 in gap, which is 26 boards of 16 ft, plus a 10% allowance for cut ends and defects: 29 boards, or 464 linear feet. The row count comes from the pitch, not from the area: a 5 1/2 in board plus 3/16 in of gap is a 5 11/16 in pitch, and 144 in divided by that is 25.3, which rounds up to 26 rows.
At 16 in on centre in Southern pine, a 2x8 spans 11 ft 10 in and is the first size that fails a 12 ft span, so the answer is a 2x10 (14 ft 0 in) — or the same 2x8 at 12 in on centre, which reaches 13 ft 1 in. Those are Table R507.6 values for No. 2 grade at 40 psf live and 10 psf dead load.
Post spacing is set by the beam, and the beam is set by the joist span it carries. A double 2x10 beam in Southern pine carrying 10 ft joists spans 8 ft 0 in between posts, so a 16 ft deck with that beam needs three posts at 8 ft. A triple 2x10 reaches 10 ft 0 in for the same joists: a 24 ft beam then divides into three bays of 8 ft and four posts, where the double would have needed five.
A 16 in diameter footing 36 in deep is 4.19 cu ft, which is twelve 50 lb bags of fast-setting mix at 0.375 cu ft each, or seven 80 lb bags of standard mix at 0.60. The footing diameter itself comes from the tributary area and the soil: 48 sq ft of deck on 2,000 psf soil reads the 60 sq ft row of Table R507.3.1, which is a 17 in round footing, and the depth is yours to set from the frost line.
The code figure is 40 psf of live load plus 10 psf of dead load, so a 16 x 12 deck is designed for 7,680 lb of people and furniture. A 400 gallon hot tub is 3,336 lb of water alone: 17 psf spread over that deck, but about 68 psf under the tub's own 7 ft footprint — a point load the prescriptive tables do not cover, so it needs an engineer rather than a calculator.
| Value | As used here | Basis | Source |
|---|---|---|---|
| Dressed size of 5/4x6 decking | 1 in × 5 1/2 in | Surfaced size, not nominal. Every board count on this site divides by 5.5 in, never by 6 in. | ALSC, American Softwood Lumber Standard PS 20 |
| Dressed size of 2x8 / 2x10 / 2x12 framing | 1 1/2 × 7 1/4 in / 1 1/2 × 9 1/4 in / 1 1/2 × 11 1/4 in | Surfaced size. The section drawing is scaled from these, not from the nominal numbers. | ALSC, American Softwood Lumber Standard PS 20 |
| Maximum joist span, Southern pine 2x8 at 16 in on centre | 11 ft 10 in | Table R507.6 cell. The default 12 ft deck therefore cannot use a 2x8 at 16 in. | ICC, 2021 IRC Table R507.6 — deck joist spans |
| Maximum joist span, Douglas fir-larch / hem-fir / SPF 2x10 at 12 in on centre | 15 ft 8 in | Table R507.6 cell, one species group lower than Southern pine in every size. | ICC, 2021 IRC Table R507.6 — deck joist spans |
| Maximum joist span, redwood / cedars / ponderosa / red pine 2x12 at 24 in on centre | 12 ft 4 in | Table R507.6 cell; the same size in Southern pine reaches 13 ft 6 in at that spacing. | ICC, 2021 IRC Table R507.6 — deck joist spans |
| Beam span, Southern pine double 2x10 under 12 ft joists | 7 ft 4 in | Table R507.5(1) cell, which is also the maximum post spacing for that beam. | ICC, 2021 IRC Table R507.5(1) — deck beam spans, 40 psf live load |
| Beam span, Douglas fir-larch / hem-fir / SPF triple 2x8 under 10 ft joists | 7 ft 11 in | Table R507.5(1) cell. Cantilever at each end is capped at a quarter of the span. | ICC, 2021 IRC Table R507.5(1) — deck beam spans, 40 psf live load |
| Minimum footing, 48 sq ft tributary area on 2,000 psf soil | 14 in round / 12 in square, 6 in thick | Table R507.3.1 row for 40 psf live load. A 2,500 psf soil is read from the 2,000 psf column, never the 3,000 one. | ICC, 2021 IRC Table R507.3.1 — minimum footing size for decks |
| Design live and dead load on a deck | 40 psf live + 10 psf dead | The load case the deck tables are tabulated for; the floor live load table (Table R301.5) sets the 40 psf for decks. | ICC, 2021 IRC Table R507.6 — deck joist spans |
| Joist cantilever limit | Lesser of the tabulated value and a quarter of the joist span | Section R507.6 text, not the table: the number in the table is a cap, not a target. | ICC, 2021 IRC Table R507.6 — deck joist spans |
| Maximum joist spacing for 1 1/4-inch wood decking | 12 in single span / 16 in multiple span, 8 in and 12 in at 45° | Table R507.7. A board on two joists is single span; on three or more it is multiple span. | ICC, 2021 IRC Table R507.7 — maximum joist spacing for wood decking |
| Bags of concrete per cubic foot | 50 lb fast-setting = 0.375 cu ft; 80 lb concrete mix = 0.60 cu ft | The manufacturers’ own yields: the same hole takes 11 bags of one and 7 of the other. | QUIKRETE Fast-Setting Concrete Mix, data sheet 1004-50 |
| Deck stain coverage | 250–600 sq ft per gallon | A product page, not a code: coverage depends on the wood and the coat. Editable in the form. | Cabot Australian Timber Oil, product page |
| Feet to metres | 1 ft = 0.3048 m exactly | The international foot, so the metric column is a conversion and not a second measurement. | NIST SP 811, Guide for the Use of the SI |
These are estimating tools, not a structural design. Spans are transcribed from the 2021 IRC prescriptive tables for No. 2 grade at 40 psf live and 10 psf dead load, and they only apply to a deck that matches those assumptions: an attached ledger, a built-up beam, posts on footings below the frost line, and the fasteners and connections the code requires. Your local building department, the permit drawings and a licensed engineer decide what is allowed on your site.