10 ft span, Southern pine
- Smallest that reaches it
- 2x8 at 12 in
- Span
- 13' 1"
JoyOne factory · deck takeoff
Pick the species, the size and the spacing, and the answer is the table cell — with the cantilever cap beside it and the whole table highlighted so you can see how much the next size up would buy you.
14' 0" maximum span
2x10 · 16 in o.c. · cantilever 3' 6"
Southern pine · 2x10 · 16 in on centre
14' 0"reaches your span
IRC 2021 Table R507.7: 1 1/4-inch decking, multiple span — 16 in perpendicular, 12 in at 45°.
| Size | 12 in | 16 in | 24 in | |
|---|---|---|---|---|
| 2 × 6 | 9′ 11″ | 9′ 0″ | 7′ 7″ | |
| 2 × 8 | 13′ 1″ | 11′ 10″ | 9′ 8″ | |
| 2 × 10 | 16′ 2″ | 14′ 0″ | 11′ 5″ | |
| 2 × 12 | 18′ 0″ | 16′ 6″ | 13′ 6″ |
Every number below comes from the same engine that runs in the browser, at build time, so the examples cannot drift from the calculator above.
A joist span is measured between the faces of its supports, not from the house to the end of the deck. If the joist hangs from a ledger on the house and bears on a beam 11 ft 6 in away, the span is 11 ft 6 in; anything past the beam is a cantilever and is counted separately, with its own limit. Getting that wrong in the optimistic direction is how people end up with a springy floor and a beam that is carrying load it was never sized for.
The table is indexed by three things and you need all three: species group, nominal size, and spacing. Southern pine is the strongest of the three groups at every size, the Douglas fir-larch / hem-fir / spruce-pine-fir group sits below it, and the redwood / cedars / ponderosa / red pine group below that. The differences are not small — at 2x10 and 16 in on centre it is 14 ft 0 in against 13 ft 7 in against 13 ft 0 in — and they are why the species stamped on the board matters as much as its size.
Every value is No. 2 grade with the wet service factor applied, at 40 psf live and 10 psf dead load, deflecting L/360 at the main span. A Select Structural board would span more and a stud grade would span less; if the stamp is not No. 2, the table is not your table. Pressure-treated lumber is wet when it is installed and shrinks as it dries, which is what the wet service factor is for.
The form offers Southern pine, Douglas fir-larch, hem-fir, spruce-pine-fir and redwood-or-cedar, because those are the names on the tags at a lumber yard. The table has three groups, because that is how ICC tabulated it: the three middle species share one row set, with incising assumed, and the western species share another. The calculator says which group it read, so a hem-fir answer is never presented as if it had its own column.
Incising is the reason those three share a row. Incising cuts small slits into the surface so preservative penetrates, and it costs section, which is why an incised Douglas fir board is not the same board as an unincised one. The redwood and cedar group carries a footnote that its design values assume northern species with no incising, which is a detail worth reading before you assume cedar is stronger than it is.
If your yard sells "SPF" as a mixed stamp, that is the spruce-pine-fir option and it reads from the middle group. If it sells a species the table does not name — western red cedar versus incense cedar, for example — the conservative move is to use the weakest group, not the closest name.
You cannot pick 24 in on centre just because the joist spans further at that spacing: the decking has to be allowed to span it. Table R507.7 limits joist spacing by decking material and by whether the board is single span or multiple span. For 1 1/4-inch wood decking the limit is 12 in single span and 16 in multiple span perpendicular, falling to 8 in and 12 in at 45°. For 2-inch decking it is 24 in perpendicular, single or multiple, and 18 or 24 in diagonal.
Single span means the board sits on exactly two joists, which happens at the rim and at any change in direction; multiple span means three or more. A 24 in layout that gives 16 in decking only one or two supports at the edge of the deck is a layout that will cup there, which is why the narrow limits exist.
The reverse lookup on this page lists every size and spacing that reaches the span you type, so you can see the trade rather than take the first passing row. Going from 16 in to 12 in on centre often lets you drop a size, and dropping a size usually saves more money than the extra joists cost — but it also means the decking can be no wider than 12 in, which rules out most 5/4 boards laid perpendicular.
Table R507.6 prints a maximum cantilever for each cell, and the text of the section caps it again: the cantilever shall not exceed one quarter of the joist span. For a 2x10 at 16 in on centre in Southern pine the table says 3 ft 6 in and a quarter of the 14 ft 0 in span is 3 ft 6 in, so the two agree. For a 2x12 the table says 4 ft 2 in and a quarter of 16 ft 6 in is 4 ft 1 1/2 in, so the cap is the smaller number and the cap governs.
A cantilever is not free span. It is designed at L/180 with a 220 lb point load on its end, which is a foot on the end of a board, not a hot tub. The overhang also has to be built so the joist is continuous over the beam, not spliced at it, and the rim joist at the end has to be able to carry the load back — which is why a cantilever longer than a couple of feet usually gets blocking between the joists at the beam.
Set the cantilever to zero if you are not sure. A flush beam with the joists hanging from it on both sides has no cantilever at all, and it is the simpler detail to inspect. The cost is that the beam has to be deeper than the joists to clear them, which is a conversation with the beam page rather than this one.
Four numbers that decide the answer
The span tells you the joist size; it does not tell you the joist length. Add the cantilever, add the bearing at each end — 1 1/2 in on wood or metal, 3 in on concrete or masonry, per R507.6.1 — and round up to a stock length. A 12 ft span with a 1 ft cantilever and two bearings is 13 ft 3 in of board, so a 14 ft joist and 9 in of cut-off, not a 12 ft joist and a splice.
It also does not tell you the connections. Every joist that frames into a ledger or the side of a beam needs a hanger, and the hanger needs the right nails: the ones in the box are usually the right ones, the ones in the coffee can are not. Lateral restraint at the bearing points is required too — hangers or blocking at 60% of the joist depth, or a rim joist nailed with three 10d or three #10 screws per joist.
If the answer is "nothing in the table reaches it", the fix is structural rather than arithmetic: add a beam to shorten the span, drop the spacing, or move up to an engineered member. This page will not invent a 20 ft 2x10. The beam page is the place to go next, because shortening the joist span by adding a mid-span beam usually costs less than the next size up in every joist on the deck.
In Southern pine at 16 in on centre, 11 ft 10 in; at 12 in, 13 ft 1 in; at 24 in, 9 ft 8 in. In Douglas fir, hem-fir or SPF the same 2x8 spans 11 ft 1 in at 16 in. These are IRC 2021 Table R507.6 values for No. 2 grade at 40 psf live and 10 psf dead load.
14 ft 0 in at 16 in on centre in Southern pine, 13 ft 7 in in Douglas fir, hem-fir or SPF, and 13 ft 0 in in redwood or cedar. At 12 in on centre the same sizes reach 16 ft 2 in, 15 ft 8 in and 14 ft 11 in.
Yes: the table is tabulated per spacing because a joist at 12 in carries half the deck area of one at 24 in. A Southern pine 2x10 reaches 16 ft 2 in at 12 in, 14 ft 0 in at 16 in and 11 ft 5 in at 24 in. But the decking sets a ceiling on the spacing, so 24 in is only available for 2-inch or rated decking.
The lesser of the table value and a quarter of the joist span. For a Southern pine 2x10 at 16 in on centre the table says 3 ft 6 in and a quarter of the 14 ft span is also 3 ft 6 in. For a 2x12 at 16 in the table says 4 ft 2 in but the quarter-span cap is 4 ft 1 1/2 in, so the cap governs.
No. 2 grade with the wet service factor applied, at 40 psf live load and 10 psf dead load, deflecting L/360. A Select Structural board spans further and a stud-grade board less, so a table answer only applies to a board with No. 2 (or better, in the same species group) on its stamp.
| Value | As used here | Basis | Source |
|---|---|---|---|
| Dressed size of 5/4x6 decking | 1 in × 5 1/2 in | Surfaced size, not nominal. Every board count on this site divides by 5.5 in, never by 6 in. | ALSC, American Softwood Lumber Standard PS 20 |
| Dressed size of 2x8 / 2x10 / 2x12 framing | 1 1/2 × 7 1/4 in / 1 1/2 × 9 1/4 in / 1 1/2 × 11 1/4 in | Surfaced size. The section drawing is scaled from these, not from the nominal numbers. | ALSC, American Softwood Lumber Standard PS 20 |
| Maximum joist span, Southern pine 2x8 at 16 in on centre | 11 ft 10 in | Table R507.6 cell. The default 12 ft deck therefore cannot use a 2x8 at 16 in. | ICC, 2021 IRC Table R507.6 — deck joist spans |
| Maximum joist span, Douglas fir-larch / hem-fir / SPF 2x10 at 12 in on centre | 15 ft 8 in | Table R507.6 cell, one species group lower than Southern pine in every size. | ICC, 2021 IRC Table R507.6 — deck joist spans |
| Maximum joist span, redwood / cedars / ponderosa / red pine 2x12 at 24 in on centre | 12 ft 4 in | Table R507.6 cell; the same size in Southern pine reaches 13 ft 6 in at that spacing. | ICC, 2021 IRC Table R507.6 — deck joist spans |
| Beam span, Southern pine double 2x10 under 12 ft joists | 7 ft 4 in | Table R507.5(1) cell, which is also the maximum post spacing for that beam. | ICC, 2021 IRC Table R507.5(1) — deck beam spans, 40 psf live load |
| Beam span, Douglas fir-larch / hem-fir / SPF triple 2x8 under 10 ft joists | 7 ft 11 in | Table R507.5(1) cell. Cantilever at each end is capped at a quarter of the span. | ICC, 2021 IRC Table R507.5(1) — deck beam spans, 40 psf live load |
| Minimum footing, 48 sq ft tributary area on 2,000 psf soil | 14 in round / 12 in square, 6 in thick | Table R507.3.1 row for 40 psf live load. A 2,500 psf soil is read from the 2,000 psf column, never the 3,000 one. | ICC, 2021 IRC Table R507.3.1 — minimum footing size for decks |
| Design live and dead load on a deck | 40 psf live + 10 psf dead | The load case the deck tables are tabulated for; the floor live load table (Table R301.5) sets the 40 psf for decks. | ICC, 2021 IRC Table R507.6 — deck joist spans |
| Joist cantilever limit | Lesser of the tabulated value and a quarter of the joist span | Section R507.6 text, not the table: the number in the table is a cap, not a target. | ICC, 2021 IRC Table R507.6 — deck joist spans |
| Maximum joist spacing for 1 1/4-inch wood decking | 12 in single span / 16 in multiple span, 8 in and 12 in at 45° | Table R507.7. A board on two joists is single span; on three or more it is multiple span. | ICC, 2021 IRC Table R507.7 — maximum joist spacing for wood decking |
| Bags of concrete per cubic foot | 50 lb fast-setting = 0.375 cu ft; 80 lb concrete mix = 0.60 cu ft | The manufacturers’ own yields: the same hole takes 11 bags of one and 7 of the other. | QUIKRETE Fast-Setting Concrete Mix, data sheet 1004-50 |
| Deck stain coverage | 250–600 sq ft per gallon | A product page, not a code: coverage depends on the wood and the coat. Editable in the form. | Cabot Australian Timber Oil, product page |
| Feet to metres | 1 ft = 0.3048 m exactly | The international foot, so the metric column is a conversion and not a second measurement. | NIST SP 811, Guide for the Use of the SI |
These are estimating tools, not a structural design. Spans are transcribed from the 2021 IRC prescriptive tables for No. 2 grade at 40 psf live and 10 psf dead load, and they only apply to a deck that matches those assumptions: an attached ledger, a built-up beam, posts on footings below the frost line, and the fasteners and connections the code requires. Your local building department, the permit drawings and a licensed engineer decide what is allowed on your site.