JoyOne factory · deck takeoff

Deck Load Calculator: How Much Weight Can a Deck Hold at 40 psf Live?

Type the deck and, if you have one, the hot tub. The answer is the load in pounds, the load per square foot, and how far past the 40 psf the code assumes you have gone.

40 psf live + 10 psf deadHot tub water weightPoint load warningNo sign-off

The calculator

Deck size
ft

The direction the boards and the beam run.

ft

The joist span the tables are read for.

Load
psf
psf
gal

0 if there is no tub. Water is 8.34 lb per gallon.

lb

9,600 lb · 50.0 psf

0% of the 40 psf live allowance

Design load

16' 0" × 12' 0" = 192 sq ft

9,600 lb50.0 psf over the deck

Live load
7,680 lb40 psf
Dead load
1,920 lb10 psf
Hot tub water
0 lbno tub
People
0 lb0 × 180 lb
Where the pounds come from.
LoadPoundspsf of deck
Live load (code allowance)7,68040.0
Dead load1,92010.0
Hot tub water00.0
People00.0
Total9,60050.0

Worked examples

Every number below comes from the same engine that runs in the browser, at build time, so the examples cannot drift from the calculator above.

20 people, no tub

Total
13,200 lb · 68.8 psf
Live allowance
47% used

400 gal tub, 4 people

Total
13,656 lb · 71.1 psf
Live allowance
53% used

600 gal tub, 6 people

Total
15,684 lb · 81.7 psf
Live allowance
79% used

Where 40 and 10 come from

The deck tables are tabulated for a 40 psf live load and a 10 psf dead load. The 40 is the floor live load the code assigns to decks — the same figure as a residential room, because a deck full of people at a party is the load case that governs. The 10 psf dead load covers the decking, the joists and the railing; it is not the weight of the frame plus a hot tub.

So a 16 × 12 deck is designed for 192 sq ft × 50 psf = 9,600 lb of which 7,680 lb is expected to be people, furniture and whatever else moves. That is roughly 40 adults standing evenly, which sounds like a lot until you put them all at one end for a photograph. The 40 psf is an average over the whole deck, not a promise about any one square foot.

The dead load deserves a second look on a composite deck. Composite boards are heavier than wood, a hidden fastener system adds a little, and a pergola or a heavy railing adds more. Ten psf is generous for a bare wood deck and it is not generous for a deck with a pergola on it, which is one of the reasons a loaded deck belongs in front of an engineer.

A hot tub is water, and water is heavy

Water is 8.34 lb per gallon, so a 400 gallon spa holds 3,336 lb before you count the shell, the heater, the cover or the people in it. Spread over the 7 ft square the spa actually touches, that is 68 psf of water alone; add a 900 lb shell and four bathers and it is close to 90 psf under the footprint, near double the design live load and concentrated in one place.

Spread over the whole deck, the same water is only 17 psf on a 16 × 12, which is why the average looks harmless and the reality is not. Structural failure follows the local number, not the average: the joists under the tub see the 90, and the beam sees the reaction from the joists nearest the tub, which is why a tub on a deck is a beam and footing question as much as a decking one.

A tub also has a dead-load problem that people forget: it is there all year. Snow, then water, then a cover, then a person climbing in — the load never comes off. A deck designed for a party at 40 psf has a different life from a deck carrying 4,000 lb in the same corner for fifteen years, and creep in wet lumber is real.

Point loads are what psf hides

Pounds per square foot is an averaging unit, and it hides the thing that breaks decks: a load concentrated on a small area. A piano, a planter, a hot tub foot, a stair stringer bearing on a rim joist and a 220 lb person standing on the end of a cantilever are all point loads, and none of them is checked by multiplying area by 50.

The one place the deck tables do acknowledge a point load is the cantilever: the maximum overhang is checked at L/180 with a 220 lb point load on its end. That is a foot on the end of a board, and it is the reason a cantilever is limited to a quarter of the span rather than to whatever the bending maths would allow.

So the useful reading of the number this page returns is a check on the average, not on the corner. If the tub, the piano or the planter sits over a post, the load goes almost straight down and the deck is mostly a platform. If it sits mid-span between two posts, the joists and the beam are carrying it in bending, and that is where the deflection shows up as a sag you can see from the garden.

Reading the bar, and what "over" means

The comparison bar on this page puts the extra load — water in a tub, a crowd on the decking — against the 40 psf the tables assume. Under 100% and the extras still fit inside the allowance the tables were computed for; over 100% and they do not, because there is no row for more than 40 psf live. That is the whole meaning of the warning: not "this will collapse", but "the table you are about to read no longer applies".

The number of people is a second, smaller check. At 180 lb each, ten people on a 192 sq ft deck is 1,800 lb, or 9.4 psf — nowhere near the limit. Fifty people at once is 46.9 psf, which trips it. That is why the 40 psf figure is described as a crowd: it takes a real crowd to reach it, and it takes a tub to exceed it casually.

Remember what the bar is not. It is not a structural analysis, it does not know where the load sits, and it cannot see a rotten joist, a missing hanger or a ledger bolted into siding. Those are the actual failure modes on residential decks, and they are all invisible to a load calculation — which is why the code spends more words on connections than on spans.

The four numbers this page works with

When the answer is an engineer, not a bigger calculator

A hot tub, a rooftop deck, a deck over a basement, a deck carrying a pergola or a snow load, or anything over about 200 sq ft with an unusual shape: those are engineered jobs. Not because the arithmetic is hard, but because the load path is no longer the one the prescriptive tables describe, and the connections need designing rather than copying.

The same is true of an existing deck. Nobody knows what is under the decking until it is opened up, and a deck built in 1985 to a 1985 code is not a deck that can be checked against a 2021 table without looking at what is actually there. If the question is "can this deck hold my tub", the answer starts with a screwdriver and an inspection, not with this page.

What this page is good for is the honest middle: knowing whether your plan is inside the prescriptive envelope, and knowing when it is not. It will tell you that a 400 gallon tub puts you outside, it will show you by how much, and it will refuse to give you a structural verdict — which is the correct answer, and the one worth paying an engineer for.

Questions that come up before the first hole

How much weight can a deck hold?

A deck built to the prescriptive tables is designed for 40 psf live plus 10 psf dead, so a 16 × 12 deck is designed for 7,680 lb of people and furniture. That is an average over the whole surface: it does not mean any one square foot can take 40 lb, and it says nothing about a point load like a tub foot or a piano leg.

How much does a hot tub weigh on a deck?

A 400 gallon spa holds 3,336 lb of water. Add a 700 to 1,000 lb shell, a cover and four bathers and the package is around 4,700 lb. Spread over a 7 ft square footprint that is about 96 psf — roughly double the 40 psf live load the tables assume, and concentrated rather than averaged.

What is the difference between live load and dead load?

Dead load is what stays: decking, joists, beam, railing, and anything permanently built on. Live load is what moves: people, furniture, snow, water in a tub. The deck tables assume 10 psf dead and 40 psf live, and a heavier permanent structure — composite boards, a pergola — eats into the dead allowance.

Does a deck need to be designed for snow?

Yes, wherever it snows. The deck tables are tabulated for a ground snow load case, and the beam tables have separate columns for 50, 60 and 70 psf ground snow. If your jurisdiction publishes a ground snow load, the prescriptive spans for your deck are the snow columns, not the 40 psf live load ones.

Can this calculator tell me if my deck is safe?

No, and it will not pretend to. It compares your planned load with the 40 psf the tables assume. Whether an existing deck can carry a tub depends on the condition of the joists, the ledger connection, the footings and the soil — all of which need someone to look at them.

Every number on this site, with where it came from

ValueAs used hereBasisSource
Dressed size of 5/4x6 decking1 in × 5 1/2 inSurfaced size, not nominal. Every board count on this site divides by 5.5 in, never by 6 in.ALSC, American Softwood Lumber Standard PS 20
Dressed size of 2x8 / 2x10 / 2x12 framing1 1/2 × 7 1/4 in / 1 1/2 × 9 1/4 in / 1 1/2 × 11 1/4 inSurfaced size. The section drawing is scaled from these, not from the nominal numbers.ALSC, American Softwood Lumber Standard PS 20
Maximum joist span, Southern pine 2x8 at 16 in on centre11 ft 10 inTable R507.6 cell. The default 12 ft deck therefore cannot use a 2x8 at 16 in.ICC, 2021 IRC Table R507.6 — deck joist spans
Maximum joist span, Douglas fir-larch / hem-fir / SPF 2x10 at 12 in on centre15 ft 8 inTable R507.6 cell, one species group lower than Southern pine in every size.ICC, 2021 IRC Table R507.6 — deck joist spans
Maximum joist span, redwood / cedars / ponderosa / red pine 2x12 at 24 in on centre12 ft 4 inTable R507.6 cell; the same size in Southern pine reaches 13 ft 6 in at that spacing.ICC, 2021 IRC Table R507.6 — deck joist spans
Beam span, Southern pine double 2x10 under 12 ft joists7 ft 4 inTable R507.5(1) cell, which is also the maximum post spacing for that beam.ICC, 2021 IRC Table R507.5(1) — deck beam spans, 40 psf live load
Beam span, Douglas fir-larch / hem-fir / SPF triple 2x8 under 10 ft joists7 ft 11 inTable R507.5(1) cell. Cantilever at each end is capped at a quarter of the span.ICC, 2021 IRC Table R507.5(1) — deck beam spans, 40 psf live load
Minimum footing, 48 sq ft tributary area on 2,000 psf soil14 in round / 12 in square, 6 in thickTable R507.3.1 row for 40 psf live load. A 2,500 psf soil is read from the 2,000 psf column, never the 3,000 one.ICC, 2021 IRC Table R507.3.1 — minimum footing size for decks
Design live and dead load on a deck40 psf live + 10 psf deadThe load case the deck tables are tabulated for; the floor live load table (Table R301.5) sets the 40 psf for decks.ICC, 2021 IRC Table R507.6 — deck joist spans
Joist cantilever limitLesser of the tabulated value and a quarter of the joist spanSection R507.6 text, not the table: the number in the table is a cap, not a target.ICC, 2021 IRC Table R507.6 — deck joist spans
Maximum joist spacing for 1 1/4-inch wood decking12 in single span / 16 in multiple span, 8 in and 12 in at 45°Table R507.7. A board on two joists is single span; on three or more it is multiple span.ICC, 2021 IRC Table R507.7 — maximum joist spacing for wood decking
Bags of concrete per cubic foot50 lb fast-setting = 0.375 cu ft; 80 lb concrete mix = 0.60 cu ftThe manufacturers’ own yields: the same hole takes 11 bags of one and 7 of the other.QUIKRETE Fast-Setting Concrete Mix, data sheet 1004-50
Deck stain coverage250–600 sq ft per gallonA product page, not a code: coverage depends on the wood and the coat. Editable in the form.Cabot Australian Timber Oil, product page
Feet to metres1 ft = 0.3048 m exactlyThe international foot, so the metric column is a conversion and not a second measurement.NIST SP 811, Guide for the Use of the SI

Sources

These are estimating tools, not a structural design. Spans are transcribed from the 2021 IRC prescriptive tables for No. 2 grade at 40 psf live and 10 psf dead load, and they only apply to a deck that matches those assumptions: an attached ledger, a built-up beam, posts on footings below the frost line, and the fasteners and connections the code requires. Your local building department, the permit drawings and a licensed engineer decide what is allowed on your site.